• Automatic Stator Testing Machine for Generator Such as Bosch
  • Automatic Stator Testing Machine for Generator Such as Bosch
  • Automatic Stator Testing Machine for Generator Such as Bosch
  • Automatic Stator Testing Machine for Generator Such as Bosch
  • Automatic Stator Testing Machine for Generator Such as Bosch

Automatic Stator Testing Machine for Generator Such as Bosch

Warranty: 12 Months
Color: Customized
Dimension: 600mmx600mmx2200mm
Stator Testing Service: Engineers Avaiable to Service Overseas
Condition: New
Customized Service: Provided
Gold Member Since 2020

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
WIND-DTS-100
Transport Package
Wooden Case
Specification
Middle Size
Trademark
Wind Automation
Origin
China
HS Code
8479811000
Production Capacity
100 Sets/Year

Product Description

Automatic Stator Testing Machine for Bosch Generator
Automatic Stator Testing Machine for Generator Such as Bosch
This testing machine covers a wide application, not only for alternaotr stator, but also for AC motor, Hybrid car motor stators. 
 
(1) Testing time
Item DC resistance Balance of resistance Turn to turn short circuit Insulation resistance Hipot Interphase insulation Interphase hipot
Parameter 0.05s/loop 0.1s/time 1 impulse/ time 1s/time 1s/time 1s/time 1s/time
Time 1.5s/6 loop 0.1s 1s 1s 1s 1s 1s

(2) Testing item: all the testing items can be conducted alone or together.      
1)DC resistance test
Testing range:0.01W - 1000W
Testing loop:6 loop(scalable)
Tolerance:±0.5 %
Testing method:Four points, with auto ambient temperature correction function

2)Inductance test(including 3 phase balance test)
Testing range:10mH - 500mH
Testing loop:6 loop(scalable)
Tolerance: ±2.5%
Testing method:Four points

3)Turn to turn insulation
Pulse high voltage: 100V-3000V (100V / step)
Pulse peak: 0.5msec
Sampling frequency: 1-40 MHZ
Testing loop:6 loop(scalable)
Tolerance: ±2.5%
Judging method: area difference judgment (sensitive to inductance and energy loss)
Standard waveform is White,OK waveform is Green, NG waveform is Red     

4)Insulation resistance
Voltage:DC500V /1000V
Testing time:1-10s(adjustable)
Judging range:1-1000 MW
Tolerance: ±2.5%

5)Interphase insulation
Voltage:DC500V /1000V
Testing time:1-10s(adjustable)
Judging range:1-1000 MW
Tolerance: ±2.5%

6)Interphase hipot
Voltage:AC100-3000V (100V/step)
Testing time:1-10s(adjustable)
Judging range:0.1 mA --  20 mA
Tolerance: ±2.5%

7)Hipot(with arc detection)
Voltage:AC100-3000V (100V/step)
Testing time:1-10s(adjustable)
Judging range:0.1 mA -- 20 mA
Tolerance: ±2.5%

8)Balance of resistance
Test method: DC resistance sampling
Testing time:0.1s
Judging method:percentage method adopted to judge the difference of DC resistance between windings.


 

Car Generator Alternator Stator Testing Machine Quality Analysis WIND-DTS-120
 

1. Advantage

 

1) Fast clamping fixture can be fitted for 3 terminal wires

2) Pneumatic fixutre is widely used to test 3 terminal wires or 6 end wires

 

2.Testing item: all the testing items can be conducted alone or together.

1)DC resistance test

Testing range:0.01W - 1000W

Testing loop:6 loop(scalable)

Tolerance:±0.5 %

Testing method:Four points, with auto ambient temperature correction function

 

2)Inductance test(including 3 phase balance test)

Testing range:10mH - 500mH

Testing loop:6 loop(scalable)

Tolerance: ±2.5%

Testing method:Four points

 

3)Turn to turn insulation

Pulse high voltage: 100V-3000V (100V / step)

Pulse peak: 0.5msec

Sampling frequency: 1-40 MHZ

Testing loop:6 loop(scalable)

Tolerance: ±2.5%

Judging method: area difference judgment (sensitive to inductance and energy loss)

Standard waveform is White,OK waveform is Green, NG waveform is Red

 

4)Insulation resistance

Voltage:DC500V /1000V

Testing time:1-10s(adjustable)

Judging range:1-1000 MW

Tolerance: ±2.5%

 

5)Interphase insulation

Voltage:DC500V /1000V

Testing time:1-10s(adjustable)

Judging range:1-1000 MW

Tolerance: ±2.5%

 

6)Interphase hipot

Voltage:AC100-3000V (100V/step)

Testing time:1-10s(adjustable)

Judging range:0.1 mA -- 20 mA

Tolerance: ±2.5%

 

7)Hipot(with arc detection)

Voltage:AC100-3000V (100V/step)

Testing time:1-10s(adjustable)

Judging range:0.1 mA -- 20 mA

Tolerance: ±2.5%

 

8)Balance of resistance

Test method: DC resistance sampling

Testing time:0.1s

Judging method:percentage method adopted to judge the difference of DC resistance between windings.

 

3.Testing time

Item DC resistance Balance of resistance Turn to turn short circuit Insulation resistance Hipot Interphase insulation Interphase hipot
Parameter 0.05s/loop 0.1s/time 1 impulse/ time 1s/time 1s/time 1s/time 1s/time
Time 1.5s/6 loop 0.1s 1s 1s 1s 1s 1s
 

 

 

 


Automatic Stator Testing Machine for Generator Such as Bosch
Automatic Stator Testing Machine for Generator Such as Bosch
Automatic Stator Testing Machine for Generator Such as Bosch

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2020

Suppliers with verified business licenses

Manufacturer/Factory
Registered Capital
5000000 RMB
Plant Area
1001~2000 square meters